RAISED FLOOR BRUSH GROMMETS

Today’s modern computer rooms or data centers house more and more high tech equipments requiring that their systems are kept in strictly controlled environments . Your IT equipment is generating ever increasing heat, driving up your costs to cool it. For the maximum performance and minimum down time it is imperative that the equipment is keep at a controlled temperature and free from dirt and dust particles.
 

Raised floor brush grommets seal cable openings

Brush grommets: raised floor brush grommets, wire management, cable management, cable organizers, data center floor grommets, data center raised floor grommets, wall edge brush grommets. Data centers contain literally miles of cables. The cabling provides both high voltage power to the room as well as network data cables. Wherever the cables enter the room there is the possibility for loss of cooling air as well as entry of dirt and dust particles. Your data center may be equipped with a suitable cooling system able to provide the capacity to supply conditioned air; however the improper delivery and containment of the system may not be meeting its needs. This results in the loss of equipment as well as increased down time.

Cable opening allows on average a massive 60% of conditioned air to escape. With the cost of energy these days that represents a huge, needless expense. The solution is simple and doesn’t require spending more money on energy.

Raised floor grommets

That’s where the raised floor grommets come in. These brush grommets prevent unwanted leakage of airflow from your data center by sealing every cabling entry point. The result is an increase in the static pressure in the under-floor plenum making sure that the data center stays at a pressure above atmospheric. Using the grommets maximizes your cooling system output making sure that all controlled air stays within your data center and reaches where you want it to reach.

The grommets typically show a return on investment in less than a year and help to reduce the overall power needs of your data center by maximizing efficiency of your cooling system.

Features include:
  • Self- sealing and interwoven closure system
  • Brush grommets can be installed before or after a data center is designed or equipment is installed
  • Available in a multitude of sizes, suitable for all applications
  • Usually doesn’t require any changes to existing wiring configuration
  • Fits into the raised floor tiles prior to cabinet installation
Benefits of the system:
  • Maximizes efficiency of your existing cooling system
  • Reduces the need to purchase additional cooling equipment
  • Maximizes equipment reliability and lengthens equipment lifetime
  • Maintains a constant static pressure
  • Makes sure your cooling system reaches out, reducing “hot spots”

Brush grommets: raised floor brush grommets, wire management, cable management, cable organizers, data center floor grommets, data center raised floor grommets, wall edge brush grommets.

Raised floor grommet component